DSO active differential probe with 100x and 1000x attenuation ranges and voltage measurements up to +/-1400 V. Bandwidth to 100 MHz. Powered by 4 AA batteries or optional 6V DC mains adapter.
Applications include:
Precise power semiconductor device measurements
Switching power supply design
Precise measurement of power converters
Precise measurement of motor drived
Features:
Up to +/-1400V differential
100 MHz bandwidth (-3 dB)
High accuracy +/-2 percent
High CMRR
Accessories: spring loaded hook probes, 4 AA batteries, manual
Input Voltage:
Differential Voltage (DC+Peak AC): ±140 V/±1400 V
Common-Mode Voltage (DC+Peak AC): ±1400 V or 1000 Vrms
Absolute Max. Voltage (DC+Peak AC): ±1400 V or 1000 Vrms CAT III
Output Voltage:
Swing: ±7 V (into 50 kΩ load)
Offset (Typ.): ±5 mV
Noise (Typ.): 0.9 mVrms
Source Impedance (Typ.): 50 kΩ
CMRR (Typ.): -80 dB@60 Hz; -50 dB@1 MHz
Operating Temperature/Humidity: -10° to +40° C / 25% to 85% RH
Storage Temperature/Humidity: -30° to +70° C / 25% to 85% RH
Cable Length: 95 cm
Input Leads Length: 30 cm
Weight: 500 g
Dimensions: 202mm x 83mm x 38mm
RoHS (2002/95/EC)
Compliant